User’s Guide ADI-8 DS © RME
4.2 Quick Start Operation
After connection of all cables and power-on of the device, the configuration of the ADI-8 DS
begins in the CLOCK section. Choose a clock source and a sample rate.
Connect the TRS-jacks or the D-sub connector with the analog signal source. Change the input
sensitivity by pressing A/D REFERENCE until the input level is sufficient to avoid noisy opera-
tion. Try to achieve an optimum input level by adjusting the source itself. Raise the source’s
output level until the red Over LED flashes at the loudest parts of the signal, then reduce the
level a bit until no more Overs are detected.
The analog line inputs of the ADI-8 DS can be accessed by using D-sub (for an optional XLR
multicore) and 1/4" TRS jacks. Both are internally connected, so not operational at the same
time. The electronic input stage is built in a servo balanced design which handles unbalanced
(mono TS) and balanced (XLR, stereo TRS jacks) correctly, automatically adjusting the level
reference.
On the DA-side just choose the desired digital input by pressing D/A INPUT. A coarse correc-
tion of the analog output level can be done by pressing the D/A REFERENCE button.
The ADI-8 DS stores all current settings and automatically activates them when the device is
turned on.